BCL2 Recombinant Antibody AE00104

$520,00

Selective and specific mouse recombinant antibody clone rBCL2/796 to human BCL2

See all our BCL2 antibodies

Official Symbol: BCL2

GeneID: 596

Swiss-Prot: P10415

Description

BCL2

All names and symbols: Apoptosis regulator BCL-2; B-cell CLL/lymphoma-2; BCL2; PPP1R50

Host speciesMouse
ClonalityRecombinant
IsotypeIgG1, kappa
Confirmed species reactivityHuman
Confirmed applicationsIHC, PA, WB
Aeonian Rating®90
RRIDAB_2736888

Immunohistochemistry (IHC):

AE00104 to BCL2 was successfully used to stain cells primarily in the germinal centre of human spleen sections. Recommended concentration: 0.3-1ug/ml

IHC of human spleen stained with BCL-2/BCL2 Mouse Recombinant Antibody AE00104
Human spleen with AE00104

Formaldehyde-fixed, paraffin-embedded human spleen stained with BCL2 Mouse Recombinant Antibody AE00104 at 0.5-1ug/ml for 30 minutes at RT. Epitope retrieval: Boiling at pH9 for 10-20 min followed by 20 min cooling. DAB staining by HRP polymer.

Western Blot (WB):

AE00104 to BCL2 was successfully used to stain an approx. 26kDa band in lysates of cell lines A431, MCF7 and U937. Recommended concentration: 0.3-1ug/ml

WB of MCF7 stained with BCL-2/BCL2 Mouse Recombinant Monoclonal Antibody AE00104
MCF7 with AE00104

Western Blot of a MCF7 lysate (30ug) stained with BCL2 Mouse Recombinant Antibody AE00104 at 0.5-1ug/ml (1h at ambient temp). ECL staining by HRP.

WB of A431, MCF7 and U937 stained with BCL-2/BCL2 Mouse Recombinant Monoclonal Antibody AE00104
A431, MCF7, U937 with AE00104

Western Blot of A431, MCF7 and U937 lysates (30ug) stained with BCL2 Mouse Recombinant Antibody AE00104 at 0.5-1ug/ml (1h at ambient temp). ECL staining by HRP.

Evidence of mono-specificity (in native PA):

Specificity and selectivity of AE00104 to BCL2 were tested against >19,000 full-length human proteins on a human protein array. A protein BLAST search against H. sapiens revealed the following closely related other proteins: BCL2L1 (isf BCLX), BCL2L2 and BAX. All these were part of the array used and showed no cross-reactivity signals.

AE00104 on protein array
AE00104 on HuProt(TM) array

Cross-reactivity assessment of BCL2 Mouse Recombinant Antibody AE00104 (1ug/ml) on CDI’s Protein Array containing more than 19,000 full-length human proteins.
The Z-score represents the strength of a signal that an antibody (through a fluorophore-tagged secondary reagent) produces when binding to a particular protein on the array. Z-scores are in units of standard deviations (SD’s) above the mean value of all signals generated on that array. When Z-scores are arranged in descending order, the difference between two successive values will be the S-score for the first. Thus, the S-score represents the relative specificity of the antibody to its intended target. An antibody is considered specific to its intended target, when it has an S-score of at least 2.5. For example, if an antibody binds to intended protein X with a Z-score of 43 and to the cross-reacting protein Y with a next Z-score of 14, then the S-score for the antibody to intended target X equals 29 (43-14).

Evidence of molecular integrity:

SDS-PAGE Analysis of Purified BCL2 Mouse Recombinant Antibody AE00104. Confirmation of Purity and Integrity of Antibody.

Coomassie-stained AE00104
AE00104 Coomassie bands

Integrity of the purified antibody AE00104 under non-reduced and reduced conditions, showing intact IgG at around 150kDa (NR) and intact heavy and light chains at 50kDa and 30kDa resp. (R)

ExpirationIntegrity warranted for 24 months after purchase when handled and stored according to instructions, see below.
Storage instructionsAvoid repeated freeze/thaw cycles. For long term storage, keep small aliquots at -20°C or -80°C and keep one aliquot at 4°C for daily experimentations. Azide will preserve antibody at 4°C for 6-12 months, when kept away from direct sun light.
WarrantyThis product is only warranted for the specifications as described in this product sheet and only when the product is handled and stored according to instructions. User should validate this antibody in the application and tissue/cell type as required, after confirmation of integrity upon receipt is obtained by reproducing the performance as described below. Should such confirmation not be attempted, any warranty is void. In case of non-conformance, user needs to contact us immediately for replacement or refund.
LiabilityThis product is for in vitro research use only. Any other applications, such as diagnostics or therapeutics, or in vivo experiments, and the validation of this product therein, are solely at the responsibility of the buyer/user.
Product Data Sheet
Material Safety Data Sheet

Additional information

Purification

By Protein G from bioreactor concentrate

Immunogen

Recombinant full-length BCL2 human protein

Epitope

Unknown

Cellular localization

Endoplasmatic Reticulum, ER, nuclear membranes, outer mitochondrial membranes

Positive Controls

follicular lymphoma, HeLa, HL-60, Jurkat, K562, spleen, tonsil

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

You may also like…