TROP2 Monoclonal Antibody AE00187

520,00

Selective and specific mouse monoclonal antibody clone TACSTD2/2152 to human TROP2

See all our TROP2 antibodies

Official Symbol: TACSTD2

GeneID: 4070

Swiss-Prot: P09758

Description

TROP2

All names and symbols: Cell surface glycoprotein Trop-2; Membrane component chromosome 1 surface marker 1; Tumor Associated Calcium Signal Transducer 2; Pancreatic carcinoma marker protein GA733-1; EGP-1; EGP1; GA733-1; GA7331; GP50; M1S1; TACSTD2; TROP2

Host speciesMouse
ClonalityMonoclonal
IsotypeIgG1, kappa



Confirmed species reactivityHuman
Confirmed applicationsICC, IHC, PA
Aeonian Rating®82
RRIDAB_2752232



Immunocytochemistry (ICC):

AE00187 to TROP2 was successfully used to stain plasma membranes in cell line MCF7. Recommended concentration: 1-3ug/ml

MCF7 with AE00187

Confocal microscopy of MCF7 stained with TROP2 Mouse Monoclonal Antibody AE00187 at 1-2ug/ml (1h at ambient temp). Detection by CF488 (green) for the antibody and RedDot (red) for nuclear staining.

Immunohistochemistry (IHC):

AE00187 to TROP2 was successfully used to stain plasma membranes of malignant cells in sections of human colon carcinoma and of human pancreas carcinoma. Recommended concentration: 1-3ug/ml

IHC of human colon carcinoma stained with TROP2 Mouse Monoclonal Antibody AE00187
Human colon carcinoma with AE00187

Formaldehyde-fixed, paraffin-embedded human colon carcinoma stained with TROP2 Mouse Monoclonal Antibody AE00187 at 1-2ug/ml for 30 minutes at RT. Epitope retrieval: Boiling at pH6 for 10-20 min followed by 20 min cooling. DAB staining by HRP polymer.

IHC of human pancreas carcinoma stained with TROP2 Mouse Monoclonal Antibody AE00187
Human pancreas carcinoma with AE00187

Formaldehyde-fixed, paraffin-embedded human pancreas carcinoma stained with TROP2 Mouse Monoclonal Antibody AE00187 at 1-2ug/ml for 30 minutes at RT. Epitope retrieval: Boiling at pH6 for 10-20 min followed by 20 min cooling. DAB staining by HRP polymer.

Evidence of mono-specificity (in native PA):

Specificity and selectivity of AE00187 to TROP2 were tested against >19,000 full-length human proteins on a human protein array. A protein BLAST search against H. sapiens revealed the following closely related other protein: EpCAM. This protein was part of the array used and showed no cross-reactivity signals.

AE00187 on protein array
AE00187 on HuProt(TM) array

Cross-reactivity assessment of TROP2 Mouse Monoclonal Antibody AE00187 (1ug/ml) on CDI’s Protein Array containing more than 19,000 full-length human proteins.
The Z-score represents the strength of a signal that an antibody (through a fluorophore-tagged secondary reagent) produces when binding to a particular protein on the array. Z-scores are in units of standard deviations (SD’s) above the mean value of all signals generated on that array. When Z-scores are arranged in descending order, the difference between two successive values will be the S-score for the first. Thus, the S-score represents the relative specificity of the antibody to its intended target. An antibody is considered specific to its intended target, when it has an S-score of at least 2.5. For example, if an antibody binds to intended protein X with a Z-score of 43 and to the cross-reacting protein Y with a next Z-score of 14, then the S-score for the antibody to intended target X equals 29 (43-14).

Evidence of molecular integrity:

SDS-PAGE Analysis of Purified TROP2 Mouse Monoclonal Antibody AE00187. Confirmation of Purity and Integrity of Antibody.

Coomassie-stained AE00187
AE00187 Coomassie bands

Integrity of the purified antibody AE00187 under non-reduced and reduced conditions, showing intact IgG at around 140kDa (NR) and intact heavy and light chains at 48kDa and 22kDa resp. (R)

ExpirationIntegrity warranted for 24 months after purchase when handled and stored according to instructions, see below.
Storage instructionsAvoid repeated freeze/thaw cycles. For long term storage, keep small aliquots at -20°C or -80°C and keep one aliquot at 4°C for daily experimentations. Azide will preserve antibody at 4°C for 6-12 months, when kept away from direct sun light.
WarrantyThis product is only warranted for the specifications as described in this product sheet and only when the product is handled and stored according to instructions. User should validate this antibody in the application and tissue/cell type as required, after confirmation of integrity upon receipt is obtained by reproducing the performance as described below. Should such confirmation not be attempted, any warranty is void. In case of non-conformance, user needs to contact us immediately for replacement or refund.
LiabilityThis product is for in vitro research use only. Any other applications, such as diagnostics or therapeutics, or in vivo experiments, and the validation of this product therein, are solely at the responsibility of the buyer/user.
Product Data Sheet
Material Safety Data Sheet

Additional information

Purification

By Protein G from bioreactor concentrate

Immunogen

Recombinant fragment around aa 31-274 of human TROP2 protein (exact sequence is proprietary)

Epitope

Extracellular domain (within aa 31-274 region)

Cellular localization

cell surface, plasma membrane

Positive Controls

colon carcinoma, MCF7, pancreas carcinoma

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

SKU: AE00187 Categories: , , , Tags: , ,

You may also like…