Sandwich ELISA to human alpha-1-antitrypsin AEE0001

560,00800,00

ELISA kit for human alpha-1-antitrypsin, with data demonstrating no cross-reactivity to other members of the Serpin family.

Description

A1AT / AAT

All names and symbols: Alpha-1-antitrypsin; Alpha-1-antiproteinase; Alpha-1 protease inhibitor; Serpin A1; alpha1AT; A1A; A1AT; AAT; nNIF; PI; PI1; PRO2275

Confirmed species reactivityHuman
Sensitivity11.37 ng/ml
Linear calculation range31.25 – 1000 ng/ml
Precision intra-assay / inter-assay<10% / <12%
Aeonian Rating®90
RRID
MatrixRecovery Range (%)Average (%)
Serum (n=5)80-10291
EDTA plasma (n=5)81-10090
Heparin plasma (n=5)80-8984
Recovery: Matrices were spiked with recombinant A1AT and the recovery rates were calculated by comparing the measured value to the expected amount of A1AT in the matrices.
Matrix1:21:41:81:16
Serum (n=5)87-91%87-107%74-101%92-97%
EDTA plasma (n=5)90-105%84-101%90-101%97-108%
Heparin plasma (n=5)84-95%92-105%82-105%89-91%
Linearity: The linearity of the kit was assayed by testing serially diluted matrices spiked with a fixed amount of recombinant A1AT. The results were demonstrated by the percentage of calculated concentration related to the expected concentration of A1AT in the diluted matrices.

Calibratrion curve:

AEE0001 to A1AT was successfully used to determine the concentration of A1AT in serum, plasma and buffer. Recommended serum dilution 1:16, and EDTA plasma dilution 1:8.

Calibration curve of recombinant A1AT in buffer. HRP detection by Absorbance at 450nm.

Selectivity of the ELISA kit:

AEE0001 to A1AT was successfully confirmed selective as there were no signals found in the presence of other Serpin family members at high and low concentrations.

Selectivity was tested by comparing the signals of recombinant A1AT with related other recombinant proteins (serpin family), each at two concentrations. The other Serpin family members tested were ACT, KAL and PAI3. HRP detection by Absorbance at 450nm.

ELISA Test:

The microtiter plate provided in this kit has been pre-coated with an antibody specific to a1AT. Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody preparation specific to a1AT. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain a1AT, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of a1AT in the samples is then determined by comparing the O.D. of the samples to the standard curve.

ELISA Procedure:

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 2 hours at 37℃;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37℃;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 1 hour at 37℃;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 15-25 minutes at 37℃;
8. Add 50µL Stop Solution. Read at 450nm immediately.

Stability:

The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage conditions.
Note:
To minimize unnecessary influences on the performance, operation procedures and lab conditions, especially room temperature, air humidity and incubator temperatures should be strictly regulated. It is also strongly suggested that the whole assay is performed by the same experimenter from the beginning to the end.

Product Manual Traditional
Product Manual Ready to Use
Material Safety Data Sheet Traditional
Material Safety Data Sheet Ready to Use

Additional information

DL-a1AT-Hu (traditional) T96

Composition:
Pre-coated, ready to use 96-well strip plate 1
Plate sealer for 96 wells 2
Standard 2
Diluents buffer 1×45ml
Detection Reagent A 1×120μl
Detection Reagent B 1×120μl
TMB Substrate 1×9ml
Stop Solution 1×6ml
Wash Buffer (30 × concentrate) 1×20ml
Instruction manual 1

DL-a1AT-Hu (traditional) T48

Composition:
Pre-coated, ready to use 96-well strip plate 1
Plate sealer for 96 wells 2
Standard 2
Diluents buffer 1×22.5ml
Detection Reagent A 1×60μl
Detection Reagent B 1×60μl
TMB Substrate 1×4.5ml
Stop Solution 1×3ml
Wash Buffer (30 × concentrate) 1×10ml
Instruction manual 1

DLR-a1AT-Hu (ready-to-use) T96

Composition:
Pre-coated, ready to use 96-well strip plate 1
Plate sealer for 96 wells 2
Standard 2
Standard Diluent 1×20ml
Detection Solution A 1×12ml
Detection Solution B 1×12ml
TMB Substrate 1×9ml
Stop Solution 1×6ml
Wash Buffer (30 × concentrate) 1×20ml
Instruction manual 1

DLR-a1AT-Hu (ready-to-use) T48

Composition:
Pre-coated, ready to use 96-well strip plate 1
Plate sealer for 96 wells 2
Standard 2
Standard Diluent 1×10ml
Detection Solution A 1×6ml
Detection Solution B 1×6ml
TMB Substrate 1×4.5ml
Stop Solution 1×3ml
Wash Buffer (30 × concentrate) 1×10ml
Instruction manual 1